We have some storage for model of  ABB TTF300-E3D1 Field-mount temperature transmitter , all 100% new and brand arigin  .

We have some storage for model of ABB TTF300-E3D1 Field-mount temperature transmitter , all 100% new and brand arigin .

Model: ABB TTF300-E3D1

Supplier: HKXYTECH

Categories: Pressure Measurement

Please contact us for more information.

PRODUCT DESCRIPTION

Specification

CE Marking

The device fulfills all requirements for CE marking in

accordance with all applicable guidelines.

Electrical isolation

3.5 kV DC (approx. 2.5 kV AC), 60 s, input to output

MTBF (Mean Time Between Failures)

190 years at 40 °C (104 °F) mean ambient temperature

Input filter

50 / 60 Hz

Switch-on delay

• HART®: < 10 s (Ia ≤ 3.6 mA during switch-on cycle)

• PROFIBUS®: 10 s, max. 30 s

• FOUNDATION Fieldbus®: < 10 s

Warm-up time

5 minutes

Rise time t90

400 to 1000 ms

Measured value update

10/s with 1 sensor, 5/s with 2 sensors, depending on sensor

type and sensor circuit

Output filter

Digital filter 1st order: 0 to 100 s

Weight

• Die-cast aluminum: 1.25 kg (2.75 lb)

• Stainless steel: 2.75 kg (6.1 lb)

Housing material

• Die-cast aluminum, epoxy coated, color: gray RAL9002

• Stainless steel

Encapsulation material used for the device electronics

• Polyurethane (PUR), WEVO PU-417

Installation conditions

Mounting position: no restrictions


Electrical connection

• Thread (selectable) 2 × M20 × 1.5 / 2 × ½ in NPT /

2 × ¾ in NPT (using reducing piece),

• Ground screw external 6 mm2, M5 internal 2 × 2.5 mm2, M4

terminals for lines up to 2.5 mm2 and handheld terminal

interface

Plastic cable gland 2 × M20 1.5:

• Cable outside diameter 6 to 12 mm (0.24 to 0.47 in),

Ex: 5 to 10 mm (0.2 to 0.39 in)

• Temperature range −30 to 80 °C (−22 to 176 °F),

Ex: −20 to 80 °C (−4 to 176 °F)

• For Non-Ex:

Polyamide gray

• For intrinsically safe design, intrinsic safety,

non-incendive and dust-explosion protection:

Polyamide blue

Metal cable gland (2 × M20 × 1.5 / 2 × ½ in NPT):

• Flameproof (enclosure), explosionproof

• Cable outside diameter 3.2 to 8.7 mm (0.13 to 0.34 in)

• Temperature range: −50 to 85 °C (−58 to 185 °F)

• Additional cable outside diameters: upon request

Lightning protection

• For cable gland M20 × 1.5

(see data sheet 10/63-6.15)

• Non-Ex: type NGV220-NO

• Intrinsic safety: type NGV220-EX


TTF300-E3D1


ABB TTF300-E3D1