Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 Differential Pressure Transmitter with Diaphragm Seal System

Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 Differential Pressure Transmitter with Diaphragm Seal System

Model: 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00

Supplier: HKXYTECH

Categories: Industrial instruments

Please contact us for more information.

PRODUCT DESCRIPTION

Evaluating Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 as a matched differential-pressure and remote-seal assembly

 

Industrial buyers searching for Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 usually need three things at the same time: correct product identity, usable technical parameters and a clear boundary around configuration-dependent options. This corrected page addresses those points without repeating administrative tables.

 

One matched transmitter and seal system

Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 is identified here as a Rosemount 3051CD differential pressure transmitter with 1199 diaphragm seal system. This is a configured measuring assembly combining a 3051CD differential-pressure transmitter and a 1199 diaphragm seal system. The transmitter and seals must be evaluated together because fill fluid, capillary geometry, process connections and temperature affect response and accuracy.

 

Difficult-process pressure and level duties

Application review for Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 should start with the actual process or machine duty. Typical applications include differential pressure, pressurized-vessel level and difficult process services where direct contact with the transmitter diaphragm is undesirable. The 1199 system can protect against corrosive, viscous or extreme-temperature media when correctly configured.

 

Engineering data for the complete assembly

To obtain a technically comparable offer for Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00, the inquiry should go beyond price and availability. Send the entire transmitter/seal code, calibrated range, process pressure and temperature, vessel dimensions, seal elevations, capillary lengths, fill fluid, flange standard, diaphragm material, hazardous-area approvals and required calibration documents.

  • Keep the complete Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 phrase on the quotation and purchase order.
  • Ask the supplier to identify inclusions, exclusions and the supporting document revision.
  • Resolve technical deviations before order release rather than during receiving inspection.

 

3051CD range and 1199 seal profile

The following table gives the relevant technical profile for Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00. It appears once on this page and separates confirmed family data from configuration-dependent details.

Exact product referenceRosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00
Product typeRosemount 3051CD differential pressure transmitter with 1199 diaphragm seal system
Transmitter familyRosemount 3051CD differential pressure
Sensor range code2
Range 2 sensor limits-250 to +250 inH2O / -621.6 to +621.6 mbar
Range 2 minimum span1.67 inH2O / 4.15 mbar in current product data
Output codeA - 4...20 mA with HART digital signal
Seal familyRosemount 1199 diaphragm seal system
Seal purposeIsolates transmitter from hot, cold, corrosive, erosive or plugging process media
Configured seal detailsConnection, diaphragm material, fill fluid and capillary require full-code confirmation

 

Emerson product data identifies 3051CD as a differential-pressure transmitter and 1199 as a diaphragm-seal system. The values shown for range code 2 and HART output follow current family documentation; configured seal details remain order-code dependent.

 

Capillary handling and zero verification

Installation planning for Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 should protect the existing wiring, process and configuration evidence. Keep both sides of the matched seal system protected during handling. Installation should control capillary routing, elevation effects and temperature exposure, followed by zero verification and a calibrated loop check.

 

Why the seal system cannot be split casually

Compatibility for Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 must be established by function and configuration, not enclosure appearance. Range code 2 and output code A can be read from the transmitter string, but every later option and the 1199 seal code must be checked against the applicable Emerson ordering table. Do not separate or replace one seal without an engineering review of the complete system.

 

Rosemount assembly reference image

Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 product reference image

The image is used as a stock or family reference for Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00. Confirm the delivered label, connectors, housing and included accessories against the approved quotation.

 

Range and seal alternatives

When alternatives to Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 are discussed, use nearby families only as comparison points. Related Rosemount 3051C pressure ranges and other 1199 seal styles are available, but changing range, fill fluid or seal geometry can change static-pressure limits, response time and temperature performance.

 

Final order review for Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00

Before release, compare Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 with the nameplate, current manufacturer data and the installed application. Keep Rosemount 3051CD2A22A1BS2B4Q4Q8TK/1199DDK53DFFWJGDB00 on the RFQ, supplier offer, purchase order and incoming-inspection record so engineering and procurement review the same item.

 

 

 