Specification

CE Marking

The device fulfills all requirements for CE marking in

accordance with all applicable guidelines.

Electrical isolation

3.5 kV DC (approx. 2.5 kV AC), 60 s, input to output

MTBF (Mean Time Between Failures)

190 years at 40 °C (104 °F) mean ambient temperature

Input filter

50 / 60 Hz

Switch-on delay

• HART®: < 10 s (Ia ≤ 3.6 mA during switch-on cycle)

• PROFIBUS®: 10 s, max. 30 s

• FOUNDATION Fieldbus®: < 10 s

Warm-up time

5 minutes

Rise time t90

400 to 1000 ms

Measured value update

10/s with 1 sensor, 5/s with 2 sensors, depending on sensor

type and sensor circuit

Output filter

Digital filter 1st order: 0 to 100 s

Weight

• Die-cast aluminum: 1.25 kg (2.75 lb)

• Stainless steel: 2.75 kg (6.1 lb)

Housing material

• Die-cast aluminum, epoxy coated, color: gray RAL9002

• Stainless steel

Encapsulation material used for the device electronics

• Polyurethane (PUR), WEVO PU-417

Installation conditions

Mounting position: no restrictions

Electrical connection

• Thread (selectable) 2 × M20 × 1.5 / 2 × ½ in NPT /

2 × ¾ in NPT (using reducing piece),

• Ground screw external 6 mm2, M5 internal 2 × 2.5 mm2, M4

terminals for lines up to 2.5 mm2 and handheld terminal

interface

Plastic cable gland 2 × M20 1.5:

• Cable outside diameter 6 to 12 mm (0.24 to 0.47 in),

Ex: 5 to 10 mm (0.2 to 0.39 in)

• Temperature range −30 to 80 °C (−22 to 176 °F),

Ex: −20 to 80 °C (−4 to 176 °F)

• For Non-Ex:

Polyamide gray

• For intrinsically safe design, intrinsic safety,

non-incendive and dust-explosion protection:

Polyamide blue

Metal cable gland (2 × M20 × 1.5 / 2 × ½ in NPT):

• Flameproof (enclosure), explosionproof

• Cable outside diameter 3.2 to 8.7 mm (0.13 to 0.34 in)

• Temperature range: −50 to 85 °C (−58 to 185 °F)

• Additional cable outside diameters: upon request

Lightning protection

• For cable gland M20 × 1.5

(see data sheet 10/63-6.15)

• Non-Ex: type NGV220-NO

• Intrinsic safety: type NGV220-EX

… Specification

Ambient conditions

Ambient temperature

• Standard: −40 to 85 °C (−40 to 185 °F)

• Optional: −50 to 85 °C (−58 to 185 °F)

• Limited temperature range during operation with LCD

indicator: −20 to 70 °C (−4 to 158 °F)

• Limited temperature range with explosion-proof design:

see corresponding certificate

• Limited temperature range with MID certification:

see corresponding certificate

Transport / Storage temperature

−50 to 85 °C (−58 to 185 °F)

Climate class in accordance with DIN EN 60654-1

Cx −40 to 85 °C (−40 to 185 °F) at 5 to 95 % relative air

humidity

Max. permissible humidity in accordance with

IEC 60068-2-30

100 % relative air humidity

Vibration resistance in accordance with IEC 60068-2-6

10 to 2000 Hz at 5 g, during operation and transport

Shock resistance in accordance with IEC 68-2-27

gn = 30, during operation and transport

IP rating

IP 66 and IP 67, NEMA 4X, ENCL 4X

Electromagnetic compatibility

Emitted interference in accordance with IEC EN 61326 and

Namur NE 21.

Interference-resistant in accordance with IEC 61326 and

Namur NE 21.

Pt100: measuring range 0 to 100 °C (32 to 212 °F), span 100 K

Type of test Testing accuracy Effect

Burst to signal- / data lines 2 kV < 0.5 %

Static discharge

• Contact plate (indirect)

• Supply terminals*

• Sensor terminals*

8 kV

6 kV

4 kV

No

No

No

Radiated field

80 MHz to 2 GHz 10 V/m < 0.5 %

Coupling

150 kHz to 80 MHz 10 V < 0.5 %

Surge

between the supply lines 0.5 kV No malfunction

Line to ground 1 kV

* Air discharge (at 1 mm (0.04 in) distance)

SIL functional safety

Only for devices with HART communication.

With conformity according to IEC 61508 for the use in safety

relevant applications up to and including SIL 3 (redundant).

• In the use of one transmitter the device fulfills the

requirements according to SIL 2.

• In the use of redundant handled transmitters the

requirements can be fulfilled according to SIL 3


TTF300 with MID certification

The temperature transmitter TTF300 is certified by an MID

Parts Certificate in accordance with the Measuring

Instruments Directive 2014/32/EU (MID) and the standard

WELMEC 7.2. The device with the appropriate configuration is

therefore approved for ‘Custody Transfer’ measurements

(fiscal metering).

The MID certification emphasizes the high accuracy, reliability

and durability of the TTF300 .

Note

This chapter provides basic information on the MID-certified

transmitter TTF300 . Before commissioning the device, full

information should be consulted in the supplied MID

documents (Parts Certificate and associated Description).

Any generally applicable statements on the transmitter

TTF300 , especially pertaining to explosion protection and

device safety, remain unaffected.

General

Devices with MID certification have their own EU declaration

of conformity. In addition to the declaration, the ‘Parts

Certificate’ and the associated ‘Description’ are enclosed

with the device.

It is compulsory and imperative that the described areas of

application, requirements and restrictions are complied with

for the intended use of the device!

The requirements of explosion protection and functional

safety (SIL) remain unaffected by the MID certification.

The number of the partial certificate (TC10833) of the notified

body NMi Certin B.V. and the checksum (0x46c9) of the

certified SW revision 01.03.00 are printed on the name plate

of the device.

Areas of application, conditions and requirements

The temperature transmitter TTF300 with MID certification

for custody transfer measurements is especially suited for

measurement and control systems in the oil and gas industry.

In addition to gas, any liquids except for water are permitted

for measurement.

The MID certification refers to a special configuration of the

transmitter. This must not be modified! An extract of the

conditions and requirements stated in the certificate follows

below:

• Communication protocol: HART 5, HART 7

• HW revision: 1.07

• SW revision: 01.03.00 with checksum 0x46c9

• The checksum of the software (firmware) is printed on

the name plate of the device

• On sensor Pt100 in a four-wire circuit

• Permissible measuring range: −50 to 150 °C

(−58 to 302 °F)

• Ambient temperature range with and without LCD

indicator: −10°C to 70 °C (14 to 158 °F)

Note

The MID certification can generally be combined with all

certifications of explosion protection.

The ambient temperature and measuring range named in the

corresponding explosion protection certificate, however,

limit the ranges permitted in the MID certificate.

Note

The HW write protection on the device should be activated

after installation and configuration. The housing cover should

be secured and the device housing sealed using the supplied

seal.


ABB TTF300  picture


TTF300-E1-C-1-H-BF-K2-M5


Need more production information for ABB TTF300-E1-C-1-H-BF-K2-M5 , please contact me here.

My contact details

Telephone:86-027-85880977

Mobile :86-13545206420(Whatapp&Wechat is available)

Fax:86-027-85309780

Skype:Diana@hkxytech.com

E-mail: Diana@hkxytech.com or Dianatian118@gmail.com


Related Products