Document power redundancy, uplink media and recovery behavior for Hirschmann GRS106-6F8T16TSGGY9HHSE2A99XX.X.XX
Hirschmann GRS106-6F8T16TSGGY9HHSE2A99XX.X.XX, part number 942 287 008, is the Hirschmann GRS106-24TX/6SFP-2HV-2A configuration recorded in the Belden source. Dual high-voltage power gives this GRS106 configuration an additional resilience option. Fiber modules and failover behavior still require project-specific verification.
Coordinate redundant paths
Design and test the intended power or network recovery around Hirschmann GRS106-6F8T16TSGGY9HHSE2A99XX.X.XX with its actual peers. Record normal paths, the selected failure case and application results; two connected supplies or links do not prove useful resilience by themselves.
Include power resilience in the design
Hirschmann GRS106-6F8T16TSGGY9HHSE2A99XX.X.XX is listed for Power supply input 1: 110 - 240 VAC, 50 Hz - 60 Hz , Power supply input 2: 110 - 240 VAC, 50 Hz - 60 Hz with consumption recorded as 32 W. Verify protection, conductor sizing, both supply paths where applicable and the available power at the installed point; include PoE load and enclosure heat in the same review.
| Complete ordering phrase | Hirschmann GRS106-6F8T16TSGGY9HHSE2A99XX.X.XX |
|---|---|
| Catalog Type | GRS106-24TX/6SFP-2HV-2A |
| Part Number | 942 287 008 |
| Product class | GREYHOUND 105/106 Series, Managed Industrial Switch, fanless design, 19" rack mount, according to IEEE 802.3, 6x1/2.5/10GE +8x1/2.5GE +16xGE |
| Port / media summary | 30 Ports in total, 6x GE/2.5GE/10GE SFP(+) slot + 8x FE/GE/2.5GE TX ports + 16x FE/GE TX ports |
| Operating voltage | Power supply input 1: 110 - 240 VAC, 50 Hz - 60 Hz , Power supply input 2: 110 - 240 VAC, 50 Hz - 60 Hz |
| Power consumption | 32 W |
| Operating temperature | -10 - +60 |
| Mounting / protection | Rack mount / IP30 |
| Dimensions / weight | 444 x 44 x 310 mm / 5 kg estimated |
Assign every copper and optical path
The recorded interface summary for Hirschmann GRS106-6F8T16TSGGY9HHSE2A99XX.X.XX is: 30 Ports in total, 6x GE/2.5GE/10GE SFP(+) slot + 8x FE/GE/2.5GE TX ports + 16x FE/GE TX ports. Assign each endpoint and uplink before installation, including medium, rate, peer, network zone and reserved capacity. Keep the accepted port map with part number 942 287 008.

Hirschmann industrial networking reference image for GRS106-24TX/6SFP-2HV-2A; verify the delivered unit by full product code and label.
Do not substitute by family name alone
A replacement review for Hirschmann GRS106-6F8T16TSGGY9HHSE2A99XX.X.XX should compare the installed label, rack fit, supply, copper and SFP assignments, software scope and required approvals. Document every difference before accepting an alternative to part number 942 287 008.
Leave a concise acceptance record
Commission Hirschmann GRS106-6F8T16TSGGY9HHSE2A99XX.X.XX by checking the label, mounting and power, then connecting the approved port map and testing representative application traffic. Save the final configuration where applicable and retain a short normal-state record for handover.
Information required for an exact offer
Request Hirschmann GRS106-6F8T16TSGGY9HHSE2A99XX.X.XX, Type GRS106-24TX/6SFP-2HV-2A, part number 942 287 008, quantity and destination. Add the required supply, interfaces, PoE or routing scope, operating environment and accessories; ask the supplier to show the exact offered code and included items.
Keep delivery inspection concise
At delivery, match Hirschmann GRS106-6F8T16TSGGY9HHSE2A99XX.X.XX against the purchase order and label, then confirm visible connectors, supplied terminals or mounting items, documentation and condition. Note any variance before the device is moved into the installation workflow.
Keep the complete Hirschmann GRS106-6F8T16TSGGY9HHSE2A99XX.X.XX reference on the final purchase order, delivery record and installed asset register.
Manufacturer configuration reference for GRS106-24TX/6SFP-2HV-2A