Pepperl Fuchs UC2000-30GM70-2E2R2-V15 Ultrasonic Sensor with Two PNP Switching Outputs

Pepperl Fuchs UC2000-30GM70-2E2R2-V15 Ultrasonic Sensor with Two PNP Switching Outputs

Model: UC2000-30GM70-2E2R2-V15

Supplier: HKXYTECH

Categories: Barriers and sensors

Please contact us for more information.

PRODUCT DESCRIPTION

Placing two switching points within the usable detection zone of Pepperl Fuchs UC2000-30GM70-2E2R2-V15 while checking the target and nearby sensors

 

Pepperl Fuchs UC2000-30GM70-2E2R2-V15 is an ultrasonic direct-detection sensor with a 100–2000 mm sensing range and two PNP switching outputs. The adjustment range starts at 150 mm, and the first 100 mm is a dead band. Its 12–30 V DC supply and five-pin M12 connector should be checked against the installed machine interface.

 

Detection zone and electrical specification

Item to compareProduct information and required confirmation
Sensor referencePepperl Fuchs UC2000-30GM70-2E2R2-V15
Sensing range100–2000 mm
Adjustment range150–2000 mm
Dead band0–100 mm
Operating supply12–30 V DC
Outputs2 PNP switching outputs; NO, NC programmable
Response delay≤100 ms
ConnectionM12 × 1, 5-pin
ProtectionIP65

 

Three distance figures with different meanings

When laying out Pepperl Fuchs UC2000-30GM70-2E2R2-V15, distinguish the sensing range, adjustment range and dead band. These are not interchangeable descriptions of where a switchpoint should be set. Mark the closest target approach and the intended switching positions on the machine drawing. This simple geometry check helps prevent a purchasing decision that assumes every distance from the sensor face is equally usable.

 

Use a representative target

The target for Pepperl Fuchs UC2000-30GM70-2E2R2-V15 should be described by size, shape, orientation and motion. A small or angled surface can produce a different response from the standard target used for published data. Plan the application test around the actual object and its least favorable position. The purchase specification should include those conditions rather than rely only on the maximum range printed in a catalogue.

 

Two outputs need two clear functions

  1. For Pepperl Fuchs UC2000-30GM70-2E2R2-V15, document what each switching output represents in the control program.
  2. The two points may serve separate positions or operating conditions; their meaning should be visible in the loop or machine record.
  3. Preserve output logic and settings when replacing an installed sensor.
  4. A successful electrical connection does not establish that both points are configured for the intended process behavior.

 

Nearby ultrasonic devices

The manufacturer lists synchronization options for Pepperl Fuchs UC2000-30GM70-2E2R2-V15. Where several ultrasonic sensors share an area, identify their locations and consult the appropriate configuration guidance. Do not assume independent operation will give the same result in every layout. Include adjacent devices in the survey so the engineer can decide whether coordinated operation is required for the application.

 

Pepperl Fuchs UC2000-30GM70-2E2R2-V15 shared reference image

Shared reference image supplied for the Pepperl Fuchs UC2000-30GM70-2E2R2-V15 inquiry; the pictured equipment does not confirm the exact model or delivered configuration.

 

Connection and programming scope

  • Confirm the five-pin mating cable for Pepperl Fuchs UC2000-30GM70-2E2R2-V15 and identify whether configuration accessories are part of the job.
  • The documented product supports parameterization through the specified interface and software accessories.
  • Record the accepted configuration method with the spare.
  • A quote for Pepperl Fuchs UC2000-30GM70-2E2R2-V15 should distinguish the sensor from any tool or cable that the site does not already possess.

 

Avoid merging the UC2000 variants

Related IE2R2, UE2R2 and other UC2000 designations require their own interface review. Compare them with Pepperl Fuchs UC2000-30GM70-2E2R2-V15 by output type, connector and functional arrangement before approving an alternative. Keep the complete 2E2R2-V15 ending visible in the purchase line. A family-level description such as ultrasonic distance sensor does not fully define this two-switch-output requirement.

 

A useful commissioning record

After installation of Pepperl Fuchs UC2000-30GM70-2E2R2-V15, retain the final switching positions, output logic and the target conditions used for the approved checks. At receipt, compare the delivered label and accessories with the accepted quote. The resulting record should allow another technician to understand how Pepperl Fuchs UC2000-30GM70-2E2R2-V15 is used without reverse-engineering the machine program or guessing from potentiometer positions.

 

Related Products