ABB TF96-96 Thermal Overload Relay for AF80 and AF96 Motor Starter Maintenance

ABB TF96-96 Thermal Overload Relay for AF80 and AF96 Motor Starter Maintenance

Model: TF96-96

Supplier: HKXYTECH

Categories: Low voltage products

Please contact us for more information.

PRODUCT DESCRIPTION

Which Starter Details Matter When Replacing ABB TF96-96 and Preserving the Motor Protection Arrangement?

 

ABB TF96-96 is an ABB thermal overload relay identified by product number 1SAZ911201R1006. Its 84–96 A adjustment band and class 10 trip characteristic define a particular protection choice. Selecting this spare begins with the existing motor feeder and the reason for replacement, rather than treating the relay as a generic accessory for any contactor.

 

A maintenance decision, not just a matching enclosure

For ABB TF96-96, record the protected motor, feeder designation and the setting found on the removed unit. Then compare those details with the approved motor record. If the machine has been changed since commissioning, an old adjustment may no longer represent the intended protection design. Buying the same housing does not resolve that discrepancy.

 

What the adjustment band tells purchasing

The stated band for ABB TF96-96 helps distinguish it from neighboring TF96 versions. It does not select the final setting for an individual motor. A request for ABB TF96-96 should identify the motor current and the starter connection arrangement so the responsible electrical team can confirm that the chosen relay covers the required application.

 

Product references and application decisions

Selection pointConfirmed detail or required review
Exact productABB TF96-96
Setting range84–96 A
Trip characteristicClass 10
Direct mountingAF80 and AF96 contactors
Auxiliary functionsNC trip contact, NO signal contact; selectable manual or automatic reset

 

Three observations after a trip

  • A useful fault report for ABB TF96-96 records the point in the operating cycle when the trip happened, the load condition and any recent mechanical change.
  • Keep these observations with the work order.
  • Repeatedly replacing the relay without preserving this context can obscure an overload condition elsewhere in the driven machine.

 

ABB TF96-96 shared reference image

Shared reference image associated with the ABB TF96-96 request. Confirm the actual offered unit and included accessories from the quotation and product labels.

 

Retain the operator sequence

The reset selection on ABB TF96-96 must agree with the approved restart procedure. Identify how the trip contact interrupts operation and how the separate signal contact reports the event. For ABB TF96-96, document those paths independently; restoring the relay state and issuing a machine start command are different parts of the control sequence.

 

What belongs in the spare package

Request ABB TF96-96 with the complete ABB identifier, quantity and a photograph of the existing starter. Identify any separate mounting kit or accessory required by the installation. On receipt, compare the designation and physical condition with the order before releasing the part for maintenance. Keep the approved final setting and reset mode in the asset record.

 

Return-to-service evidence

After authorized work on ABB TF96-96, retain the verification outcome for the stop and indication functions. The useful handover connects the replacement unit to the motor it protects and the control drawing used for the work. This gives the next maintenance team a concrete starting point if the same feeder later needs attention.

 

Related Products