Selecting ABB AF80-30-00-13 for a Motor Starter by Checking Switching Duty, Control Supply and the Complete Panel Assembly
The motor circuit and the control circuit ask different questions of a contactor. ABB AF80-30-00-13 combines a three-pole power-switching arrangement with an electronic coil specified for 100–250 V AC/DC. Its suitability should be assessed from the actual switching duty and starter combination, not simply from the largest current figure in a catalogue.
Two circuits, distinct ratings
| Review item | Technical information or confirmation needed |
|---|---|
| Requested product | ABB AF80-30-00-13 |
| ABB product identifier | 1SBL397001R1300 |
| Coil designation | 100–250 V AC, 50/60 Hz, or DC |
| Motor duty at 400 V AC | AC-3: 80 A; 37 kW |
| Other duty comparison | AC-1: 125 A at 690 V and 40 °C; not the AC-3 motor rating |
Begin with the load category
Use the AC-3 figures when reviewing ABB AF80-30-00-13 for the corresponding motor-switching duty. A resistive-load rating answers a different question. Write the utilization category beside every current value on the comparison sheet, especially when several suppliers describe a contactor using only an ampere number in the quotation title.

Shared reference image for the ABB AF80-30-00-13 inquiry. The image is not evidence of the exact supplied model, accessories or execution.
Check the control voltage at the machine
For ABB AF80-30-00-13, compare the coil designation with the actual control supply and its operating variation. The incoming plant voltage does not necessarily equal the panel control voltage. Record whether the coil is driven from an AC control transformer or a DC supply, together with the control drawing revision.
Review the starter as an assembly
- A purchase of ABB AF80-30-00-13 may also involve overload protection, short-circuit protection, interlocks and auxiliary feedback contacts.
- List those requirements individually.
- Confirm the documented coordination for the assembled starter; selecting the contactor alone does not establish the protection performance of the complete motor feeder under every fault condition.
Do not lose the feedback function
Before removing an existing ABB AF80-30-00-13, identify the contacts used for running indication, permissives or interlocking. The external auxiliary arrangement may be essential to the machine sequence. Compare the accessory configuration separately from the main poles so that a mechanically suitable replacement does not leave the controller without the expected feedback.
Receiving inspection for a panel spare
- Check the offered ABB AF80-30-00-13 label against the purchase line and inspect terminal condition before installation.
- Keep the packaging identifier associated with the unit.
- If the spare is intended for a particular starter, label its storage record with that asset reference instead of relying on a generic contactor shelf description.
Specify the intended duty in the request
An effective ABB AF80-30-00-13 inquiry includes motor nameplate data, utilization category, control voltage and the accessory scope. Attach the old assembly photograph if dimensional fit matters. Request confirmation of the complete designation and supplied accessories so the quotation can be reviewed by the person responsible for the starter design.